ERA-MAX LOW FREQUENCY RESISTIVITY INSTRUMENT

ERA-MAX is a general-purpose electromagnetic instrument designed for electrical survey on any surface
eight types of input devices
noncontact and magnetic methods of measurement

APPLICATIONS

  • Surveying for construction and examination of existing pipelines, roads, hydraulic structures;
  • Search for and surveying of deposits of ore and nonore minerals;
  • Ecology;
  • Archeology;
  • Surveying buildings' basements and subsurface utilities.
  • PURPOSE

  • Engineering survey for construction and inspection of active pipelines, roads, hydraulic facilities
  • Search and exploration of metallic and nonmetallic mineral deposits;
  • Ecology; archeology
  • Inspection of house footing and urban underground utilites
  • SURVEY METHODS

  • Electrical exploration - resistivity method (vertical electrical sounding, profiling)
  • Charge method
  • natural electric field method
  • inductive methods
  • Geomagnetics – vector measuring of the earth magnetic field
  • Noncontact probing of protective currents in pipelines
  • Pipe and cable locator
  • ERA-MAX低频电阻仪 低频电阻仪
    Magnetic Antenna – Ferroprobe era-max
    Inductive Magnetic Antenna

    SPECIFICATIONS

    Climatic Performance        

    IP-65

    Temperature Range

    -30 to +65 °С

    ERA-MAX RECEIVER

    Operation Frequencies

    DC, 0.61, 1.22, 2.44, 4.88, 50, 100, 625; 1250; 2500 Hz

    Input Voltage Range, DC    

    10 mkV±4 V (at Rinp 10mOhms);

    100mkV±4 V (at Rinp 100 mOhms)

    0,61;1,22;2,44;4.88,50,100,625;1250;2500 Гц

    0,1 мкВ-2,8 В

    Input Active Resistance      

    100 mOhms (DC)

    100 mOhms (min) (AC)

    Input Capacitance    

    15 pF (max) (AC)

    Pass band (specified by operator) 

    (2-3) % / (4-6)% (4.88, 50, 100 Hz)

    0,1 % / (0.2)% (625, 1250, 2500 Hz)

    Interference Suppression

    (50-60 Hz and radio frequencies)  

    100 dB (DC);

    100 dB (0.61, 1.22, 2.44, 4.88, 625, 1250, 2500 Hz)

    Memory Capacity    

    5200 readings

    Extraneous DC Voltage Compensation

    Automatic

    Interface      

    RS-232C

    Basic Reduced Measurement Error

    1 % (Input Voltage, DC)

    4 % (ratio of input voltage to generator output current);

     (for 0.61; 1.22; 2.44; 4.88, 625; 1250; 2500 Hz)

    Supply Voltage        

    12 V, Built-in Accumulator Unit

    Consumption Current         

    30 mА (max.)

    Internal Power

    Supply Accumulator Unit - 2000 мА АА (R6)

    Weight; Overall Dimensions

    1.2 kg 160x52x200 mm

    Connected Input Receivers 

    - Grounded Receiver Electrodes

    - Active Electrodes

    - Air Electric Antenna

    - Trail Receiving Line

    - Magnetic Antenna – Ferroprobe

    - Induction Magnetic Antenna

    ERA-MAX-LHF TRANSMITTER

    Output Regulated Current   

    1, 2, 5, 10, 20, 100, 200 mA;

    Voltage        

    to 1000 V, (DC)

    Operation Frequencies       

    0, 1.22, 2.44, 4.88, 625, 1250, 2500 Hz

    External Power Supply       

    12-24 V

    Built-in Accumulator Unit    

    2 AH (АЧ), Panasonic

    Maximum Output Power     

    40 ВА (max)

    Weight; Overall Dimensions

    2.3 kg (Including Internal Accumulator) 160x160x60 mm

    Output Current Form

    Meander

    Output Generators   

    Grounded Electrodes; Closed Loop; Trail Lines (“625 Hz)

    Rotating Field Mode

    Available (if two generators used)